Page 48 - Op_K_2025_absolute Links
P. 48

OPP-SENS® Duct absolute

         humidity temperature sensors
                                                                      Type              Item no. ADG Euro  /  pc.

                       Immersion length 50 – 150 mm:
                       Current / Voltage transmitter
                       (3-wire, 0 – 10 V / 4 – 20 mA switchable)
                       without display*                               HTa-T-I-150        103478  22  199.90
                       with display and NFC interface                 HTa-T-I-150-D-NFC  105147  22  262.90
                       Modbus transmitter (Modbus RTU)
                       without display*                               HTa-MOD-I-150      103480  22  232.60
                       with display and NFC interface                 HTa-MOD-I-150-D-NFC 105141  22  295.70
                       BACnet transmitter (MS / TP)
                       without display*                               HTa-BAC-I-150      103482  22  232.60
                       with display and NFC interface                 HTa-BAC-I-150-D-NFC  105138  22  295.70

                       Immersion length 200 – 400 mm:
                       Current / Voltage transmitter
                       (3-wire, 0 – 10 V / 4 – 20 mA switchable)
                       without display*                               HTa-T-I-400        103486  22  223.60
                       with display and NFC interface                 HTa-T-I-400-D-NFC  105148  22  286.70
                       Modbus transmitter (Modbus RTU)
                       without display*                               HTa-MOD-I-400      103488  22  256.40
                       with display and NFC interface                 HTa-MOD-I-400-D-NFC 105142  22  319.40
                       BACnet transmitter (MS / TP)
                       without display*                               HTa-BAC-I-400      103490  22  256.40
                       with display and NFC interface                 HTa-BAC-I-400-D-NFC  105139  22  319.40
                       Data sheet no. 20911
                       BACnet protocol OPP-SENS (downloadable from our website)

                       *  For programming/assigning addresses and 5P calibration, a display must be used at least once.
















































          48  |  Catalog 2025  |  Sensors                 To our online catalog: www.oprg.de/en/support/download-center