OPP-SENS® External absolute

               humidity temperature sensors
                                                                            Type              Item no. ADG Euro  /  pc.

                             OPP-SENS® External humidity temperature sensor   HTa-...-OUT
                             (absolute humidity)
                             For the measurement of absolute humidity and temperature
                             outside.
                             Display and control unit with autoadapt and capacitive
                             button (option). This enables the NFC function, allowing easy
                             sensor parameterization via a smartphone.
                             5-point calibration: linear interpolation of the output
                             curve over 5 user-defined points.                                                        SENSORS
                             10 offset points: linear shift of characteristic curve the output
                             signal via 10-level rotary switch.
                             Captive lid with 8-way positioning.

                             10 measurement ranges can be set using the rotary switch:
                             0 – 15g / m³   0 – 20g / m³   0 – 35g / m³   0 – 50g / m³*
                             0 – 100g / m³  0 – 130g / m³  0 – 150g / m³  0 – 200g / m³
                             0 – 300g / m³  0 – 500g / m³  *factory settings
                             Measuring range temperature:   Factory settings -50 to 50 °C,
                                                   with adjustable optional display
                                                   between -50 and 100 °C
                             Supply voltage:
                             2-wire                24 V DC
                             3-wire / Modbus / BACnet   24 V AC / DC
                             Output:
                             2-wire                4 – 20 mA
                             3-wire                0 – 10 V or 4 – 20 mA
                                                   switchable or bus
                             Margins of error:
                             Humidity              ± 3 % RH at 25 °C for 20 – 80 % RH
                             Temperature           ± 0.5 °C for 0 – 65 °C
                             Permiss. amb. cond.:     -20 – 70 °C, 0 – 95 % RH
                                                   (non-condensing)
                             Housing:              IP 65 including seal,
                                                   Plastic gray / yellow
                             Terminals:            Spring terminals 0.2 – 1.5 mm2
                             Cable gland:          M16
                             Current transmitter (2-wire, 4 – 20 mA)
                             without display*                               HTa-TC-OUT        103504  22  237.00
                             with display and NFC interface                 HTa-TC-OUT-D-NFC  105146  22  300.20
                             Current / Voltage transmitter
                             (3-wire, 0 – 10 V / 4 – 20 mA switchable)
                             without display*                               HTa-T-OUT         103506  22  237.00
                             with display and NFC interface                 HTa-T-OUT-D-NFC   105149  22  300.20
                             Modbus transmitter (Modbus RTU)
                             without display*                               HTa-MOD-OUT       103508  22  270.00
                             with display and NFC interface                 HTa-MOD-OUT-D-NFC  105143  22  333.20
                             BACnet transmitter (MS / TP)
                             without display*                               HTa-BAC-OUT       103510  22  270.00
                             with display and NFC interface                 HTa-BAC-OUT-D-NFC  105140  22  333.20