Page 42 - Op_K_2025_absolute Links
P. 42

OPP-SENS® External relative

         humidity temperature sensors
                                                                      Type              Item no. ADG Euro  /  pc.

                       OPP-SENS® External humidity temperature sensor   HT-...-OUT
                       (relative humidity)
                       For the measurement of relative humidity and temperature
                       outside.
                       Display and control unit with autoadapt and capacitive
                       button (option). This enables the NFC function, allowing easy
                       sensor parameterization via a smartphone.
                       5-point calibration: linear interpolation of the output
                       curve over 5 user-defined points.
                       10-offset points: linear shift of characteristic curve the output
                       signal via 10-level rotary switch.
                       Captive lid with 8-way positioning.
                       Output 1 humidity:    0 – 100 % RH linear
                       Output 2 temperature:    -50 – 50 °C linear
                       Supply voltage:
                       2-wire              24 V DC
                       3-wire / Modbus / BACnet   24 V AC / DC
                       Output:
                       2-wire              4 – 20 mA
                       3-wire              0 – 10 V or 4 – 20 mA
                                           switchable or bus
                       Margins of error:
                       Humidity            ±3 % RH at 25 °C for 20 – 80 % RH
                       Temperature         ±0.5 °C for 0 – 65 °C
                       Permiss. amb. cond.:      -20 – 70 °C, 0 – 95 % RH
                                           (non-condensing)
                       Housing:            IP 65 including seal,
                                           Plastic gray / yellow
                       Terminals:          Spring terminals 0.2 – 1.5 mm2
                       Cable gland:        M16

                       Current transmitter (2-wire, 4 – 20 mA)
                       without display*                               HT-TC-OUT          103464  22  237.00
                       with display and NFC interface                 HT-TC-OUT-D-NFC    105161  22  300.20
                       Current / Voltage transmitter
                       (3-wire, 0 – 10 V / 4 – 20 mA switchable)
                       without display*                               HT-T-OUT           103463  22  237.00
                       with display and NFC interface                 HT-T-OUT-D-NFC     105164  22  300.20
                       Modbus transmitter (Modbus RTU)
                       without display*                               HT-MOD-OUT         103465  22  270.00
                       with display and NFC interface                 HT-MOD-OUT-D-NFC   105157  22  333.20
                       BACnet transmitter (MS / TP)
                       without display*                               HT-BAC-OUT         103466  22  270.00
                       with display and NFC interface                 HT-BAC-OUT-D-NFC   105152  22  333.20
                       Data sheet no. 20909
                       BACnet protocol OPP-SENS (downloadable from our website)

                       *  For programming/assigning addresses and 5P calibration, a display must be used at least once.
















          42  |  Catalog 2025  |  Sensors                 To our online catalog: www.oprg.de/en/support/download-center
   37   38   39   40   41   42   43   44   45   46   47