Page 22 - Op_K_2025_absolute Links
P. 22

Accessories for

          OPP-SENS® Immersion temperature sensors
                                                                      Type              Item no. ADG Euro  /  pc.

                       Immersion sleeves                                     see          see        see
                       for use with standard temperature sensors and transmitters   table   table   table
                       such as cable temperature sensors with ø 6 mm.       below        below      below
                       Connection:   G½ A
                       Type:         Type ATM, PN 16 bar, Nickel-plated brass
                                     Type AT, PN 16 bar, Stainless steel 1.4571
                       Immersion depth:   See table
                       Data sheet no. 20902
                       Sizing calculator (downloadable from our website)

          Immersion sleeve type                 ADG                 Immersion depth mm Euro / pc.
                                                       50     100     150     200    250     300     450
          Type ATM, Nickel-plated brass          02   11.80   12.50  13.00   13.80   14.60  15.40   21.30
          Item no.                                    100038  100040  100041  100042  100043  100044  100046
          Type AT, Stainless steel 1.4571        02   18.30   17.90  18.50   19.80   20.40  21.10   22.30
          Item no.                                    100024  100027  100029  100031  100033  100035  100037

                       Air duct flange
                       for use with OPP-SENS® sensors.
                       For straight and round ducts with lip seal for airtight
                       seal, 2 holes for bolting to air duct.
                       The flanges are made of dark gray plastic, including
                       cross-head screw for fixing the sensor.

                       Bore diameter:
                       ø 13 mm for attaching the base temperature sensor  F-13           103041  22   3.60
                       on the housing, standard
                       ø 6 mm                                         F-6                103043  22   3.60
                       moveable along the length of the probe
                       ø 10 mm for airflow and humidity sensors       F-10               103042  22   3.60
                       moveable along the length of the probe
                       Data sheet no. 20902

                       The professional planner / executing company is responsible for selecting an immersion sleeve that is appropriate for the intended application.
                       Current local rules and regulations are to be observed, in particular:
                       •  VDE / VDI 3511 Technical temperature measurements
                       •  DIN 43772 Control technology – metal protective tubes and extension tubes for liquid-in-glass thermometers, dial thermometers,
                         thermocouples and resistance thermometers – dimensions, materials, testing
                       •   VDI Guideline 2035, page 2 – water related corrosion; preventing damage in hot water heating systems. Stainless steel tubes are
                        should be selected for cooling devices, well water and applications involving contact with food.
                       Ordering example:   Immersion sleeve with length 100 mm,
                                     Stainless steel PN 40: AT 100
                                     Nickel-plated brass: ATM 100



























          22  |  Catalog 2025  |  Sensors                 To our online catalog: www.oprg.de/en/support/download-center
   17   18   19   20   21   22   23   24   25   26   27