Page 25 - OP_Katalog_EN
P. 25

OPP-SENS® I/O module
                                                                            Type              Item no. ADG Euro  /  pc.

                             OPP-SENS® I / O module                         IO-...                       see our
                             for connecting external portable devices with relay and                     current
                             current / voltage output with spring clamps. This permits                  price list
                             integrating analog transmitters into bus networks.
                             Display and control unit with autoadapt and capacitive
                             button (option). This enables the NFC function, allowing easy
                             sensor parameterization via a smartphone.
                             Captive lid with 8-way positioning.
                                                                                                                      SENSORS
                             Supply voltage:     24 V AC / DC
                             Digital input:      configurable as closer or opener,
                                                 switchable with DIP
                             Option:             galvanically isolated digital input
                             Analog input:       3-wire 0 – 10 V or 4 – 20 mA,
                                                 switchable with DIP.
                             External transmitter
                             supply:             up to 100 mA
                             Input impedance
                             at 0 – 10 V:        10 kΩ
                             Load at 4 – 20 mA:    100 Ω
                             Permiss.
                             ambient conditions:   -20 – 70 °C, 0 – 95 % RH
                             (non-condensing)
                             Housing:            IP 65 including seal,
                                                 Plastic gray / yellow
                             Cable gland:        M16
                             Terminals:          Spring terminals 0.2 – 1.5 mm2

                             Modbus transmitter,
                             2 digital inputs    without display*           IO-MOD-S-DI2      103646  22
                                                 with display               IO-MOD-S-DI2-D-NFC  105179  22
                             1 analog- / 1 digital input   without display*  IO-MOD-S-AI1DI1  103648  22
                                                 with display               IO-MOD-S-AI1DI1-D-NFC 105177  22
                             Modbus transmitter with galvanic isolation
                             2 digital inputs    without display*           IO-MOD-S-DI2-G    103647  22
                                                 with display               IO-MOD-S-DI2-D-NFC-G 105180  22
                             1 analog- / 1 digital input   without display*  IO-MOD-S-AI1DI1-G  103649  22
                                                 with display               IO-MOD-S-AI1DI1-D-  105178  22
                                                                            NFC-G
                             BACnet transmitter,
                             2 digital inputs    without display*           IO-BAC-S-DI2      103650  22
                                                 with display               IO-BAC-S-DI2-D-NFC  105175  22
                             1 analog- / 1 digital input   without display*  IO-BAC-S-AI1DI1  103652  22
                                                 with display               IO-BAC-S-AI1DI1-D-NFC 105173  22
                             BACnet transmitter with galvanic isolation
                             2 digital inputs    without display*           IO-BAC-S-DI2-G    103651  22
                                                 with display               IO-BAC-S-DI2-D-NFC-G 105176  22
                             1 analog- / 1 digital input   without display*  IO-BAC-S-AI1DI1-G  103653  22
                                                 with display               IO-BAC-S-AI1DI1-D-  105174  22
                             Data sheet no. 20915                           NFC-G
                             BACnet protocol OPP-SENS (downloadable from our website)


                             *  For programming/assigning addresses and 5P calibration, a display must be used at least once.








               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Sensors  |  25