Page 21 - OP_Katalog_EN
P. 21

Accessories for

               OPP-SENS® Immersion temperature sensors
                                                                            Type              Item no. ADG Euro  /  pc.

                             Immersion sleeves                                     see          see      see our
                             for use with standard temperature sensors and transmitters   table   table   current
                             such as cable temperature sensors with ø 6 mm.       below        below    price list
                             Connection:   G½ A
                             Type:         Type ATM, PN 16 bar, Nickel-plated brass
                                           Type AT, PN 16 bar, Stainless steel 1.4571
                             Immersion depth:   See table
                             Data sheet no. 20902
                             Sizing calculator (downloadable from our website)                                        SENSORS

                Immersion sleeve type                 ADG                Immersion depth mm Euro / pc.
                                                             50     100     150    200     250     300    450
                Type ATM, Nickel-plated brass          02
                Item no.                                   100038  100040  100041  100042  100043  100044  100046
                Type AT, Stainless steel 1.4571        02
                Item no.                                   100024  100027  100029  100031  100033  100035  100037

                             Air duct flange
                             for use with OPP-SENS® sensors.
                             For straight and round ducts with lip seal for airtight
                             seal, 2 holes for bolting to air duct.
                             The flanges are made of dark gray plastic, including
                             cross-head screw for fixing the sensor.

                             Bore diameter:
                             ø 13 mm for attaching the base temperature sensor  F-13          103041  22
                             on the housing, standard
                             ø 6 mm                                         F-6               103043  22
                             moveable along the length of the probe
                             ø 10 mm for airflow and humidity sensors       F-10              103042  22
                             moveable along the length of the probe
                             Data sheet no. 20902

                             The professional planner / executing company is responsible for selecting an immersion sleeve that is appropriate for the intended application.
                             Current local rules and regulations are to be observed, in particular:
                             •  VDE / VDI 3511 Technical temperature measurements
                             •  DIN 43772 Control technology – metal protective tubes and extension tubes for liquid-in-glass thermometers, dial thermometers,
                               thermocouples and resistance thermometers – dimensions, materials, testing
                             •   VDI Guideline 2035, page 2 – water related corrosion; preventing damage in hot water heating systems. Stainless steel tubes are
                              should be selected for cooling devices, well water and applications involving contact with food.
                             Ordering example:   Immersion sleeve with length 100 mm,
                                           Stainless steel PN 40: AT 100
                                           Nickel-plated brass: ATM 100



























               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Sensors  |  21