Dew point monitor and sensors
                                                                            Type              Item no. ADG Euro  /  pc.

                             Dew point monitor and sensor 24 V AC / DC      O-EGH 1.5         101317  02  155.30
                             for the protection of cooling chamber ceilings against condesation,
                             contact and analog output, silicone-free design, springy supported
                             dew point sensor that connects a relay with change-over contact at
                             95 ± 4  % RH (max. 1 A 24 V AC / DC)
                             An additional analog signal 0 – 10 V is available for the range
                             of 70 – 85 % RH
                             Delivery includes tensioning belt for pipes up to ø 10 – 100 mm
                             and heat-conductive paste.                                                               SENSORS
                             Dimensions:         60 x 60 x 33 mm (L x W x D)
                             Protection class:   IP 40
                             Data sheet no. 15503

                             Dew point monitor and sensor 24 V AC / DC      KA 10             102834  02  119.70
                             low cost version for chill protection against condensation, contact,
                             and analog output silicone-free
                             Execution, relay output (SPDT) with adjustable
                             Set point (24 V AC / DC, 1 A).
                             Additional analog output 0 – 10 V.
                             Delivery includes 2 cable straps for pipes from ø 10 – 100 mm.
                             Dimensions:         85 x 95 x 50 mm (L x W x D)
                             Protection class:   IP 54
                             Data sheet no. 15515

                             OPP-SENS® Condensation switch 24 V AC/DC       CDS-CO       NEW  105990  02   96.50
                             for protection of cooling ceilings against condensation,
                             relay output (changeover contact) with adjustable switching point.
                             Integrated sensor strip.
                             Delivery includes 2 cable straps for pipes of 10 – 80 mm dia. and
                             heat conducting paste.
                             Power supply:            18 – 30 V AC/DC
                             Relay output (changeover contact):   1 A, 24 V AC/DC
                             Dimensions:              88 x 111 x 42 mm (W x H x D)
                             Protection class:        IP 65
                             Data sheet no. 15520

                             OPP-SENS® Condensation switch 24 V AC/DC       CDS-CO-2M    NEW  105996  02  105.90
                             for protection of cooling ceilings against condensation, relay output
                             (changeover contact) with adjustable switching point.
                             Separate sensor strip with 2 m cable
                             Delivery includes 2 cable straps for pipes of 10 – 80 mm dia. and
                             heat conducting paste.
                             Power supply:            18 – 30 V AC/DC
                             Relay output (changeover contact):   1 A, 24 V AC/DC
                             Dimensions:              119 x 111 x 42 mm (W x H x D)
                             Protection class:        IP 65
                             Data sheet no. 15520

                             Terminals CDS – Replacement part               CDS-PM            106004  02   13.90
                             suitable for CDS-CO and CDS-CO-2M, consisting of
                             1 x WAGO terminal 2-pole, 1 x WAGO terminal 5-pole
                             Data sheet no. 15520

                             Heat conducting paste 0.5g soft pack – Replacement part  CDS-TC  106005  02    4.90
                             suitable for CDS-CO and CDS-CO-2M
                             Data sheet no. 15520




               To our online catalog: www.oprg.de/en/support/download-center              Catalog 2025  |  Sensors  |  97