Differential pressure indicator air
                                                                      Type              Item no. ADG Euro  /  pc.

                       Differential pressure indicator, individually packaged (ATEX)  DD … EV - ATEX  s. table  11  see our
                       Complete unit (without fastening angles)                                    current
                       for vertical installation, consisting of:                                   price list
                       Differential pressure monitor and clima-set straight type 6555.

                       ATEX test certificate:    BVS 06 ATEX E 141 X

                       For monitoring air and gases in EX range zone 1 / 2 (gas) and
                       21 / 22 (dust) 1 floating change-over contact

                       Visible setting knob with target value scale.
                       2 pressure sockets to connect 6 mm PVC hose.
                       Maximum working pressure: 50 mbar
                       Output: floating change-over contact
                       Vertical installation without fastening angles is possible.
                       Data sheet no. 13102

                        Type                  Item no.           Measuring range        Directly set differen-
                        (Pressure range)                from          to                tial gap
                        DD-80-EV-ATEX          100114   20 Pa         200 Pa            10 Pa
                        DD-84-EV-ATEX          100128   30 Pa         400 Pa            15 Pa
                        DD-83-EV-ATEX          100139   50 Pa         500 Pa            20 Pa
                        DD-85-EV-ATEX          100160   200 Pa        1,000 Pa          100 Pa
                        DD-86-EV-ATEX          100172   500 Pa        2,500 Pa          150 Pa
                        DD-87-EV-ATEX          100179   1,000 Pa      5,000 Pa          250 Pa

                       Universal switching amplifier                  ExL-IR-9170        104704  01
                       For 2-point signals with inherently safe circuit to connect
                       passive floating sensors. To transfer signals from the
                       EX area to the safe area.
                       Installation on standard rails
                       ATEX test certificate:   DMT 02 ATEX E 195 X
                       Supply voltage:     24 V DC
                       Inputs:             Namur contact
                       Output:             Equipotential-free
                                           changeover contact
                       Permissible ambient
                       conditions:           -20 – 70 °C
                                           (max. 65 °C for multi-unit installation)
                                           0 – 95 % RH (non-condensing)
                                           Data sheet no. 14203



























          66  |  Catalog 2024  |  Sensors   For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1