Page 125 - OP_Katalog_EN
P. 125

GAS
                                                                                                           GAS
               Gas measuring sensor type designations



               Example:                                                        GMF  X - X - XXX - XX - XXX

               Gas measuring sensor

               Housing type:
                     1 - Plastic housing
                     2 - Square aluminium housing
                     3 - Special housing
                     4 - Rectangular aluminium housing
                     5 - Rectangular plastic housing
                     6 - Free
                     7 - Ex housing
                  UG - Air channel housing venturi tube
               DUO - 2 housings one upon the other
                      I - Infrared service interface

               Measuring principle:
               E  = Electrochemical
               H  = Semi-conductor chemical formula
               P  = Platinum electrical resistor
               Z  = Zirconium oxide
               IR = Infrared technique

               Type of gas:
               Chemical formula / abbreviation

               Measuring range:
               0   –        1 ppm     00      0   –     2,000 ppm    12
               0   –        5 ppm     01      0   –     4,000 ppm    13
               0   –       10 ppm     02      0   –    30,000 ppm    14
               0   –       20 ppm     03      0   –     5,000 ppm    18                                               GAS WARNING DEVICES
               0   –       30 ppm     04      0   –     100 % UEG    30
               0   –       50 ppm     05      0   –       1 Vol %    50
               0   –       60 ppm     06      0   –       4 Vol %    52
               0   –      100 ppm     07      0   –       5 Vol %    53
               0   –      300 ppm     08      0   –       25 Vol %   54
               0   –    3,000 ppm*    09      0   –      100 Vol %   55
               0   –     1,000 ppm    10      0   –       20 Vol %   56
               0   –     1,500 ppm    11



               Options:
               MOD     = Modbus RS485
               HP-MOD  = Modbus RS485 with integrated horn
               LON     = LONbus
               …       = other options















               * Conversion Example 3,000 ppm is equal to 0.3 vol%


               For our current prices see www.oppermann-regelgeraete.de/en/downloads/catalogue-1   Catalog 2024  |  Gas warning devices  |  125
   120   121   122   123   124   125   126   127   128   129   130